NeuroTrac Pelvitone Pelvic Floor Stimulator

PelviTone – The highest quality pelvic floor training device on the physiotherapy / rehabilitation market.  Trusted by hundreds of therapist across Canada for over 15 years!

  • Dual channel PelviTone device has all the features of Continence device, plus:
  • Advanced multi-phase programmes where treatment is split into time phases with different stimulation parameters;
  • Stronger symmetrical stimulation with the reduced Pulse Width : 50 – 330
  • Three Custom programmes plus 11 Preset Continence programmes.
  • Lock mode function to measure the home compliance (mA and time used)

What is included?

  • Pelvitone electrical stimulation unit
  • 9V Battery
  • 2 lead wires ( connects electrodes to unit)
  • User manual
  • Soft storage case
  • Probe not included 
  • Dual channel: individually isolated circuits.
  • Amplitude: 0-90 mA into 500 Ohm load; actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 86 mA, at 1500 Ohms load the maximum will be limited to 65 mA.
  • Type: Constant current, maximum output voltage 180 Volts +10 / -30 Volts
  • Waveform: Symmetrical, rectangular bi-phasic with zero DC current.
  • Selectable pulse width: 50 μS – 330 μS [2% accuracy].
  • Pulse Rate selection: in the continuous mode 2 – 100 Hz [2% accuracy].
  • Time duration of the treatment selectable: 1 minute to 90 minutes.
  • Low Battery Indicator: If the battery goes below 6.9 volts +/- 0.2 volts the battery symbol will flash on/off once every second.
  • Open Electrode Detect: If an open circuit is detected at the output of channel A or B the output current will be reset at zero.
  • Ramp up time 0.1 – 9.9 seconds.
  • If the battery voltage is below 6.6 (+/- 0.2) volts the unit will not turn on.

Physical dimensions: 134 x 69 x 29.7 mm.
Weight: 0.18 KG with battery.

Environmental Conditions for use:
+5 to +40 degrees Centigrade. 0-90% Humidity.

Environmental conditions for storage & transport:
-25 to +70 degrees Centigrade. 0-90% Humidity.

Programs on the Pelvitone®

Programme: P01 Pelvic Floor Pain  3Hz, 150uS, 1 sec ramp, Work continuous, 20 min         

Programme: P02 Urge Incontinence  10Hz, 250Us, 1 sec ramp, WORK 5 sec REST 5 sec, 20 min

Programme: P03 Stress Incontinence 1  40Hz, 200uS, 1 sec ramp, WORK 6 sec REST 15 sec, 20min

Programme: P04 Stress Incontinence 2  30Hz, 200uS, 0.8 ramp, WORK 5 sec REST 8 sec, 20 min

Programme: P05 Frequency / Urge 1  10 Hz, 200uS, 1 sec ramp, WORK 5 sec REST 5 sec, 20min

Programme: P06 Frequency / Urge 2  10Hz, 200uS, 1 sec ramp, WORK Continuous, 15min

Programme: P07 Frequency / Urge 3  10Hz, 220uS, WORK continuous, 20min

Programme: P08 Lack of Sensitivity  3-40Hz sequentially 25 min

Programme: P09 Pelvic Floor Work Out  10-30Hz sequentially 45min

Programme: P10 Building up Endurance  20Hz, 250uS, 0.8 ramp, WORK 5 sec REST 5 sec, 20min

Programme: P11 Relaxing the Pelvic Muscles  2Hz, 220uS, 1.2sec ramp, WORK 6 sec REST 10 sec, 20 min

PC 1,2 or 3 : Customizable programs Choose from the following parameters - set your own program: 2-100Hz, 50-330uS, 1-99 min , work/rest 2-99 sec OR continuous can be used, 0.1 -9.9 ramp